What are you looking for?
Flame Sensor Technology – Available for Automatic Boat Drive
The innovative flame sensor technology ensures the fastest soot-free boat combustion that is available in the market. Optimum analysis results, independant of sample quantity and sample matrix are easily achieved by any operator.
Brochures
| Title | Language | Info |
|---|---|---|
| Broschüre compEAct (DE) | de | PDF, 364 KB |
| Brochure compEAct (EN) | en | PDF, 359 KB |
| Produktkatalog Chemische Analyse (DE) | de | PDF, 909 KB |
| Product Guide Chemical Analysis (EN) | en | PDF, 886 KB |
| Flyer Accessories for multi EA 5100 (EN) | en | PDF, 304 KB |
| Flyer Zubehöre multi EA 5100 (DE) | de | PDF, 323 KB |
Flame Sensor Technology – Available for Automatic Boat Drive
The innovative flame sensor technology ensures the fastest soot-free boat combustion that is available in the market. Optimum analysis results, independant of sample quantity and sample matrix are easily achieved by any operator.
Brochures
| Title | Language | Info |
|---|---|---|
| Broschüre compEAct (DE) | de | PDF, 364 KB |
| Brochure compEAct (EN) | en | PDF, 359 KB |
| Produktkatalog Chemische Analyse (DE) | de | PDF, 909 KB |
| Product Guide Chemical Analysis (EN) | en | PDF, 886 KB |
| Flyer Accessories for multi EA 5100 (EN) | en | PDF, 304 KB |
| Flyer Zubehöre multi EA 5100 (DE) | de | PDF, 323 KB |
Flame Sensor Technology – Available for Automatic Boat Drive
The innovative flame sensor technology ensures the fastest soot-free boat combustion that is available in the market. Optimum analysis results, independant of sample quantity and sample matrix are easily achieved by any operator.
Brochures
| Title | Language | Info |
|---|---|---|
| Broschüre compEAct (DE) | de | PDF, 364 KB |
| Brochure compEAct (EN) | en | PDF, 359 KB |
| Produktkatalog Chemische Analyse (DE) | de | PDF, 909 KB |
| Product Guide Chemical Analysis (EN) | en | PDF, 886 KB |
| Flyer Accessories for multi EA 5100 (EN) | en | PDF, 304 KB |
| Flyer Zubehöre multi EA 5100 (DE) | de | PDF, 323 KB |
The innovative flame sensor technology ensures the fastest soot-free boat combustion that is available in the market. Optimum analysis results, independant of sample quantity and sample matrix are easily achieved by any operator.
Sample dosing with high precision and safety
Autoinjector AI
Intelligent constant rate syringe drive for the safe, semi-automatic injection of liquids in the vertical and horizontal operation. Developed for the multi EA 5100 series it is the smallest and lightest system available on the market. Thanks to one-step filling it is possible to reach dosing precise of autosampler, independant of the operator. The autoinjector can be equipped with up to 4 different syringes. The integrated sensors indicate automatically the installed syringe size and check for proper filling of the syringes. Thus eliminates main sources of operation mistakes. The multiWin controllled constant-speed injection ansures even for highets sample volumes a controlled and quantitative combustion process. The autoinjector is required for liquids analysis systems without autosampler. It is the ideal solution for small sample numbers resp. in case liquids analysis is seldom done.
- Free choice of dosing syringes with regards to the application and element content – 10, 20, 40, 100 µL – smart adaptation of the analysis process
- Automatic recognition of installed syrineg, syringe size and correct filling – elimination of user mistakes
- Software controlled, constat injection rates for controlled, complete combustion
- Easy software-guided operation
Resource saving – no additional power supply, extremely light and small design
Autoinjector AI-SC
Constant rate syringe drive for the semi-automatic dosing of liquid samples . This autoinjector was developed for the cpmpEAct analyzer series to enable safe injection of widely varying sample volumes. It is the ideal solution for small sample numbers, if no autosampler is present.
- Standard 50 µL syringe, can be upgraded to 100 µL
- Freely adaptable sample volumes, variable in 1 µL steps – flexibility in calibration and method optimization
- Automatic recognition of installed syringe
- Especially recommended for high element contents, EAsyCal strategy and multi element analysis
- Software controlled, constat injection rates for controlled, complete combustion
- Easy software-guided operation
- Resource saving – no additional power supply
- Space-saving – installation on top of analyzer, no extension of analyzer footprint
ABD – Automatic Boat Drive
The ABD was developed for the introduction of samples for the multi EA 5100 systems in horizontal operation mode. Therefor the samples e.g. liquids, solids, AOX (acc. batch and column method), EOX and EC/OC samples are introduced either manually or automatically into quartz sample boats. The ABD transfers the loaded quartz sample boats fully automated into the combustion furnace. The process can be adapted to the specific needs of samples resp. user preferences. Four different modes are available, constant rate, parameter mode, automatic and automatic plus. The ABD enables autmated supply of up to 100 μL liquid /EOX or up to 110 mg solid sample. There are two versions of the ABD available. One is required in case of analysis of organic sample matrices (e.g. fuels, polymers, sugar etc.), it comes equipped with the flame sensor technology as standard. The other one is suited only for analysis of innert materials and special applications like AOX, EC/OC or determination of organic surface layers on ceramic materials (e.g. cataysts). This one is not including the flame sensor.
- Cooled sample port – enables analysis of light volatile liquids
- High-performance Peltier cooóling for sample baots – minimum idletime in liquids applications
- Automatic port opening and pressure sensors – high operation safety, maximum operation comfort in solids & AOX applications
- Flame sensor technology – Intelligent fullym automatic adaptation of the combustion process to the specific needs of any matrix component – remarkably reduced downtime and maintenance effort, quantitative digestion even for huge quantities, very reactive samples or unknown matrices
- Safe and easy operation – very suited for shift work and analysis of unknown samples
- Free choice of ABD operation mode allows time and matrix optimized analysis with streamlined throughput
Sample dosing with high precision and safety
Autoinjector AI
Intelligent constant rate syringe drive for the safe, semi-automatic injection of liquids in the vertical and horizontal operation. Developed for the multi EA 5100 series it is the smallest and lightest system available on the market. Thanks to one-step filling it is possible to reach dosing precise of autosampler, independant of the operator. The autoinjector can be equipped with up to 4 different syringes. The integrated sensors indicate automatically the installed syringe size and check for proper filling of the syringes. Thus eliminates main sources of operation mistakes. The multiWin controllled constant-speed injection ansures even for highets sample volumes a controlled and quantitative combustion process. The autoinjector is required for liquids analysis systems without autosampler. It is the ideal solution for small sample numbers resp. in case liquids analysis is seldom done.
- Free choice of dosing syringes with regards to the application and element content – 10, 20, 40, 100 µL – smart adaptation of the analysis process
- Automatic recognition of installed syrineg, syringe size and correct filling – elimination of user mistakes
- Software controlled, constat injection rates for controlled, complete combustion
- Easy software-guided operation
Resource saving – no additional power supply, extremely light and small design
Autoinjector AI-SC
Constant rate syringe drive for the semi-automatic dosing of liquid samples . This autoinjector was developed for the cpmpEAct analyzer series to enable safe injection of widely varying sample volumes. It is the ideal solution for small sample numbers, if no autosampler is present.
- Standard 50 µL syringe, can be upgraded to 100 µL
- Freely adaptable sample volumes, variable in 1 µL steps – flexibility in calibration and method optimization
- Automatic recognition of installed syringe
- Especially recommended for high element contents, EAsyCal strategy and multi element analysis
- Software controlled, constat injection rates for controlled, complete combustion
- Easy software-guided operation
- Resource saving – no additional power supply
- Space-saving – installation on top of analyzer, no extension of analyzer footprint
ABD – Automatic Boat Drive
The ABD was developed for the introduction of samples for the multi EA 5100 systems in horizontal operation mode. Therefor the samples e.g. liquids, solids, AOX (acc. batch and column method), EOX and EC/OC samples are introduced either manually or automatically into quartz sample boats. The ABD transfers the loaded quartz sample boats fully automated into the combustion furnace. The process can be adapted to the specific needs of samples resp. user preferences. Four different modes are available, constant rate, parameter mode, automatic and automatic plus. The ABD enables autmated supply of up to 100 μL liquid /EOX or up to 110 mg solid sample. There are two versions of the ABD available. One is required in case of analysis of organic sample matrices (e.g. fuels, polymers, sugar etc.), it comes equipped with the flame sensor technology as standard. The other one is suited only for analysis of innert materials and special applications like AOX, EC/OC or determination of organic surface layers on ceramic materials (e.g. cataysts). This one is not including the flame sensor.
- Cooled sample port – enables analysis of light volatile liquids
- High-performance Peltier cooóling for sample baots – minimum idletime in liquids applications
- Automatic port opening and pressure sensors – high operation safety, maximum operation comfort in solids & AOX applications
- Flame sensor technology – Intelligent fullym automatic adaptation of the combustion process to the specific needs of any matrix component – remarkably reduced downtime and maintenance effort, quantitative digestion even for huge quantities, very reactive samples or unknown matrices
- Safe and easy operation – very suited for shift work and analysis of unknown samples
- Free choice of ABD operation mode allows time and matrix optimized analysis with streamlined throughput
Sample dosing with high precision and safety
Autoinjector AI
Intelligent constant rate syringe drive for the safe, semi-automatic injection of liquids in the vertical and horizontal operation. Developed for the multi EA 5100 series it is the smallest and lightest system available on the market. Thanks to one-step filling it is possible to reach dosing precise of autosampler, independant of the operator. The autoinjector can be equipped with up to 4 different syringes. The integrated sensors indicate automatically the installed syringe size and check for proper filling of the syringes. Thus eliminates main sources of operation mistakes. The multiWin controllled constant-speed injection ansures even for highets sample volumes a controlled and quantitative combustion process. The autoinjector is required for liquids analysis systems without autosampler. It is the ideal solution for small sample numbers resp. in case liquids analysis is seldom done.
- Free choice of dosing syringes with regards to the application and element content – 10, 20, 40, 100 µL – smart adaptation of the analysis process
- Automatic recognition of installed syrineg, syringe size and correct filling – elimination of user mistakes
- Software controlled, constat injection rates for controlled, complete combustion
- Easy software-guided operation
Resource saving – no additional power supply, extremely light and small design
Autoinjector AI-SC
Constant rate syringe drive for the semi-automatic dosing of liquid samples . This autoinjector was developed for the cpmpEAct analyzer series to enable safe injection of widely varying sample volumes. It is the ideal solution for small sample numbers, if no autosampler is present.
- Standard 50 µL syringe, can be upgraded to 100 µL
- Freely adaptable sample volumes, variable in 1 µL steps – flexibility in calibration and method optimization
- Automatic recognition of installed syringe
- Especially recommended for high element contents, EAsyCal strategy and multi element analysis
- Software controlled, constat injection rates for controlled, complete combustion
- Easy software-guided operation
- Resource saving – no additional power supply
- Space-saving – installation on top of analyzer, no extension of analyzer footprint
ABD – Automatic Boat Drive
The ABD was developed for the introduction of samples for the multi EA 5100 systems in horizontal operation mode. Therefor the samples e.g. liquids, solids, AOX (acc. batch and column method), EOX and EC/OC samples are introduced either manually or automatically into quartz sample boats. The ABD transfers the loaded quartz sample boats fully automated into the combustion furnace. The process can be adapted to the specific needs of samples resp. user preferences. Four different modes are available, constant rate, parameter mode, automatic and automatic plus. The ABD enables autmated supply of up to 100 μL liquid /EOX or up to 110 mg solid sample. There are two versions of the ABD available. One is required in case of analysis of organic sample matrices (e.g. fuels, polymers, sugar etc.), it comes equipped with the flame sensor technology as standard. The other one is suited only for analysis of innert materials and special applications like AOX, EC/OC or determination of organic surface layers on ceramic materials (e.g. cataysts). This one is not including the flame sensor.
- Cooled sample port – enables analysis of light volatile liquids
- High-performance Peltier cooóling for sample baots – minimum idletime in liquids applications
- Automatic port opening and pressure sensors – high operation safety, maximum operation comfort in solids & AOX applications
- Flame sensor technology – Intelligent fullym automatic adaptation of the combustion process to the specific needs of any matrix component – remarkably reduced downtime and maintenance effort, quantitative digestion even for huge quantities, very reactive samples or unknown matrices
- Safe and easy operation – very suited for shift work and analysis of unknown samples
- Free choice of ABD operation mode allows time and matrix optimized analysis with streamlined throughput
Sample dosing with high precision and safety
Autoinjector AI
Intelligent constant rate syringe drive for the safe, semi-automatic injection of liquids in the vertical and horizontal operation. Developed for the multi EA 5100 series it is the smallest and lightest system available on the market. Thanks to one-step filling it is possible to reach dosing precise of autosampler, independant of the operator. The autoinjector can be equipped with up to 4 different syringes. The integrated sensors indicate automatically the installed syringe size and check for proper filling of the syringes. Thus eliminates main sources of operation mistakes. The multiWin controllled constant-speed injection ansures even for highets sample volumes a controlled and quantitative combustion process. The autoinjector is required for liquids analysis systems without autosampler. It is the ideal solution for small sample numbers resp. in case liquids analysis is seldom done.
Resource saving – no additional power supply, extremely light and small design
Autoinjector AI-SC
Constant rate syringe drive for the semi-automatic dosing of liquid samples . This autoinjector was developed for the cpmpEAct analyzer series to enable safe injection of widely varying sample volumes. It is the ideal solution for small sample numbers, if no autosampler is present.
ABD – Automatic Boat Drive
The ABD was developed for the introduction of samples for the multi EA 5100 systems in horizontal operation mode. Therefor the samples e.g. liquids, solids, AOX (acc. batch and column method), EOX and EC/OC samples are introduced either manually or automatically into quartz sample boats. The ABD transfers the loaded quartz sample boats fully automated into the combustion furnace. The process can be adapted to the specific needs of samples resp. user preferences. Four different modes are available, constant rate, parameter mode, automatic and automatic plus. The ABD enables autmated supply of up to 100 μL liquid /EOX or up to 110 mg solid sample. There are two versions of the ABD available. One is required in case of analysis of organic sample matrices (e.g. fuels, polymers, sugar etc.), it comes equipped with the flame sensor technology as standard. The other one is suited only for analysis of innert materials and special applications like AOX, EC/OC or determination of organic surface layers on ceramic materials (e.g. cataysts). This one is not including the flame sensor.
Autoinjector – type AI-EA
Basic, robust semi-automated sample supply for liquids for multi EA 5100
Order number: 450-900.461
Autoinjector – type AI-EA
Basic, robust semi-automated sample supply for liquids for multi EA 5100
Order number: 450-900.461
Autoinjector – type AI-SC
Semi-automated sample supply for liquids for compEAct
Order number: 450-900.460
Autoinjector – type AI-SC
Semi-automated sample supply for liquids for compEAct
Order number: 450-900.460
Autoinjector – without syringe
Semi-automatic injector for small series of liquid samples
Order number: 450-900.403
Autoinjector – without syringe
Semi-automatic injector for small series of liquid samples
Order number: 450-900.403
Automatic Boat Drive – ABD with flame sensor technology
Multi-Matrix sample supply system for the horizontal operation mode with flame sensor for multi EA 5100
Order number: 450-300.013
Automatic Boat Drive – ABD with flame sensor technology
Multi-Matrix sample supply system for the horizontal operation mode with flame sensor for multi EA 5100
Order number: 450-300.013
Technical Data
|
Dimension (width x depth x height) |
|
|---|---|
|
Autoinjector – type AI-EA |
80 mm x 80 mm x 190 mm |
|
Autoinjector – type AI-SC |
150 mm x 240 mm x 270 mm |
|
Autoinjector – without syringe |
80 mm x 80 mm x 190 mm |
|
Automatic Boat Drive – ABD with flame sensor technology |
520 mm x 500 mm x 210 mm |
Standards
- APHA SM 5320 B
- ASTM D3120
- ASTM D4629
- ASTM D4744
- ASTM D5453
- ASTM D5762
- ASTM D7183
- ASTM D7184
- ASTM D7457
- DIN 15486
- DIN 38414-17
- DIN 38414-18
- DIN 51408-2
- DIN EN 14077
- DIN EN 16166
- DIN EN ISO 9562
- EN ISO 16591
- EN ISO 20846
- EPA 1650C
- EPA 450.1
- EPA 9020B
- EPA 9023
- EPA 9076
- JIS K 2541-2
- JIS K 2541-6
- NEN 6402
- OENORM 6614
- SH/T 0253
- SH/T 0689
- UOP 779
- UOP 936
- UOP 987-A
- VDI 2465-2
Order Information
|
Order number |
Description |
|---|---|
| 450-900.461 | Autoinjector – type AI-EA |
| 450-900.460 | Autoinjector – type AI-SC |
| 450-900.403 | Autoinjector – without syringe |
| 450-300.013 | Automatic Boat Drive – ABD with flame sensor technology |
Dimension (width x depth x height)
Autoinjector – type AI-EA
450-900.461
Autoinjector – type AI-SC
450-900.460
Autoinjector – without syringe
450-900.403
Automatic Boat Drive – ABD with flame sensor technology
450-300.013
Standards
- APHA SM 5320 B
- ASTM D3120
- ASTM D4629
- ASTM D4744
- ASTM D5453
- ASTM D5762
- ASTM D7183
- ASTM D7184
- ASTM D7457
- DIN 15486
- DIN 38414-17
- DIN 38414-18
- DIN 51408-2
- DIN EN 14077
- DIN EN 16166
- DIN EN ISO 9562
- EN ISO 16591
- EN ISO 20846
- EPA 1650C
- EPA 450.1
- EPA 9020B
- EPA 9023
- EPA 9076
- JIS K 2541-2
- JIS K 2541-6
- NEN 6402
- OENORM 6614
- SH/T 0253
- SH/T 0689
- UOP 779
- UOP 936
- UOP 987-A
- VDI 2465-2
Order number
Description
Newsletter Stay up to date
Social Media
Follow us on the social web.
Cookie settings
Check and adjust your cookie settings here.
Sitemap
This website uses cookies
Consent Management
We respect your right to privacy. You can decide for yourself which types of cookies you want to accept when visiting the website and which not.





