Lab Pad Steam Range TD630

Lab Pad Steam Range TD630

Category: Brand:

Laboratory Pad Steam Range, is used to carry out all pad steam processes with saturated steam, offers the shortest distance (100mm) between pader and steaming chamber.

Description

Application

Lab Pad Steam Range, a combination of padding mangle and steamer, is used to carry out all pad steam processes with saturated steam, offers the shortest time 4 seconds between padder and steaming chamber, to avoid disturbances and performs very good stability & repeatability on sulfur & vat dyestuff

Pad steam range consists of a padding mangle with two padding rollers, and a steaming chamber with a fabric holding capacity of 6m, temperature range of 98 ~ 100℃ for a dwell time of 20 ~ 120 seconds.

The steam generator is offered on request.

Specifications

Horizontal padder

Roller size Dia. about 127 mm

with legnth300 mm

Made of NBR rubber with 70o+/-5o shore hardness

Pressure 0.1 ~ 0.6mPa, 2 pressure gauges

Chemical trough capacity 500 ml

Steamer(Optional Accessories)

Power 380V 50HZ

Steam Minimum 0.4Mpa

Steaming Max 6 m, speed control 20 ~ 120 s adjustable inside the steaming chamber

All guide rollers inside the chamber is Teflon-coated

Water sealing bath at the outlet for automatic cooling control

Both steam inlet pipe and water inlet pipe size 1/2 inch is supplied by users

Weight

350 kg

Power

220V 50Hz

Dimensions

Length: 1450 mm Width: 810 mm Height: 1750 mm