What are you looking for?
The multi EA 5100 is your flexible all-rounder for sulfur, nitrogen, chlorine, and carbon analysis in solids, liquids, and gases. Benefit from the combination of outstanding robustness and sensitivity, best service, and cost-effective high-throughput analysis in every matrix – in QC laboratories, in research, or in contract analysis.
Versatile, Fast, and Sensitive – Elevate Your Measurement Performance
The modular design allows the system to be adapted to individual requirements. The basic unit can be extended at any time. Mix and match the multi EA 5100 accessory modules to suit your needs. The double furnace technology lets you achieve the best results for every sample matrix. Thanks to the easy-to-use tilting mechanism the analyzer can switch from vertical to horizontal combustion in few minutes. The multi EA 5100 is equipped with a safety system that guarantees maximum operational safety and economic life of crucial system components. Relevant system parameters are automatically monitored and optimized, guaranteeing a trouble-free and safe operation. The auto-protection system protects the analyzer from damage caused by particles, aerosols, and liquids. Optimal combustion for accurate measurements, the flame sensor guarantees matrix-optimized, quantitative combustion and prevents soot formation. Samples can be analyzed quickly and reliably.
- Double furnace – vertical and horizontal combustion combined in one system
- Intuitive user guidance, self-explanatory menu navigation
- Self Check System – automatic monitoring, adaptation and regulation of important system parameters
- Flow management system with High performance gasbox – stable gas flows, optimal digestion, prevention of soot formation by automatic leak check
- Auto Protection system – save operation, extension of components life
- Plug-and-Start technology – automatic recognition of active system configuration
- Flame sensor technology – ensuring fastest soot-free boat combustion independant of sample quantity and sample matrix
Brochures
| Title | Language | Info |
|---|---|---|
| Brochure multi EA 5100 Elemental Analysis (EN) | en | PDF, 406 KB |
| Produktkatalog Chemische Analyse (DE) | de | PDF, 909 KB |
| Product Guide Chemical Analysis (EN) | en | PDF, 886 KB |
| Flyer Accessories for multi EA 5100 (EN) | en | PDF, 304 KB |
| Flyer Zubehöre multi EA 5100 (DE) | de | PDF, 323 KB |
| Broschüre multi EA 5100 Elementanalytik (DE) | de | PDF, 401 KB |
| Flyer Bioethanol Monitoring (EN) | en | PDF, 313 KB |
| Brochure multi EA 5100 (KR) | en | PDF, 2 MB |
| Flyer Chemical Recycling of Plastics: Analytical Solutions for Crucial Quality Gates (EN) | en | PDF, 301 KB |
Versatile, Fast, and Sensitive – Elevate Your Measurement Performance
The modular design allows the system to be adapted to individual requirements. The basic unit can be extended at any time. Mix and match the multi EA 5100 accessory modules to suit your needs. The double furnace technology lets you achieve the best results for every sample matrix. Thanks to the easy-to-use tilting mechanism the analyzer can switch from vertical to horizontal combustion in few minutes. The multi EA 5100 is equipped with a safety system that guarantees maximum operational safety and economic life of crucial system components. Relevant system parameters are automatically monitored and optimized, guaranteeing a trouble-free and safe operation. The auto-protection system protects the analyzer from damage caused by particles, aerosols, and liquids. Optimal combustion for accurate measurements, the flame sensor guarantees matrix-optimized, quantitative combustion and prevents soot formation. Samples can be analyzed quickly and reliably.
- Double furnace – vertical and horizontal combustion combined in one system
- Intuitive user guidance, self-explanatory menu navigation
- Self Check System – automatic monitoring, adaptation and regulation of important system parameters
- Flow management system with High performance gasbox – stable gas flows, optimal digestion, prevention of soot formation by automatic leak check
- Auto Protection system – save operation, extension of components life
- Plug-and-Start technology – automatic recognition of active system configuration
- Flame sensor technology – ensuring fastest soot-free boat combustion independant of sample quantity and sample matrix
Brochures
| Title | Language | Info |
|---|---|---|
| Brochure multi EA 5100 Elemental Analysis (EN) | en | PDF, 406 KB |
| Produktkatalog Chemische Analyse (DE) | de | PDF, 909 KB |
| Product Guide Chemical Analysis (EN) | en | PDF, 886 KB |
| Flyer Accessories for multi EA 5100 (EN) | en | PDF, 304 KB |
| Flyer Zubehöre multi EA 5100 (DE) | de | PDF, 323 KB |
| Broschüre multi EA 5100 Elementanalytik (DE) | de | PDF, 401 KB |
| Flyer Bioethanol Monitoring (EN) | en | PDF, 313 KB |
| Brochure multi EA 5100 (KR) | en | PDF, 2 MB |
| Flyer Chemical Recycling of Plastics: Analytical Solutions for Crucial Quality Gates (EN) | en | PDF, 301 KB |
Versatile, Fast, and Sensitive – Elevate Your Measurement Performance
The modular design allows the system to be adapted to individual requirements. The basic unit can be extended at any time. Mix and match the multi EA 5100 accessory modules to suit your needs. The double furnace technology lets you achieve the best results for every sample matrix. Thanks to the easy-to-use tilting mechanism the analyzer can switch from vertical to horizontal combustion in few minutes. The multi EA 5100 is equipped with a safety system that guarantees maximum operational safety and economic life of crucial system components. Relevant system parameters are automatically monitored and optimized, guaranteeing a trouble-free and safe operation. The auto-protection system protects the analyzer from damage caused by particles, aerosols, and liquids. Optimal combustion for accurate measurements, the flame sensor guarantees matrix-optimized, quantitative combustion and prevents soot formation. Samples can be analyzed quickly and reliably.
- Double furnace – vertical and horizontal combustion combined in one system
- Intuitive user guidance, self-explanatory menu navigation
- Self Check System – automatic monitoring, adaptation and regulation of important system parameters
- Flow management system with High performance gasbox – stable gas flows, optimal digestion, prevention of soot formation by automatic leak check
- Auto Protection system – save operation, extension of components life
- Plug-and-Start technology – automatic recognition of active system configuration
- Flame sensor technology – ensuring fastest soot-free boat combustion independant of sample quantity and sample matrix
Brochures
| Title | Language | Info |
|---|---|---|
| Brochure multi EA 5100 Elemental Analysis (EN) | en | PDF, 406 KB |
| Produktkatalog Chemische Analyse (DE) | de | PDF, 909 KB |
| Product Guide Chemical Analysis (EN) | en | PDF, 886 KB |
| Flyer Accessories for multi EA 5100 (EN) | en | PDF, 304 KB |
| Flyer Zubehöre multi EA 5100 (DE) | de | PDF, 323 KB |
| Broschüre multi EA 5100 Elementanalytik (DE) | de | PDF, 401 KB |
| Flyer Bioethanol Monitoring (EN) | en | PDF, 313 KB |
| Brochure multi EA 5100 (KR) | en | PDF, 2 MB |
| Flyer Chemical Recycling of Plastics: Analytical Solutions for Crucial Quality Gates (EN) | en | PDF, 301 KB |
The modular design allows the system to be adapted to individual requirements. The basic unit can be extended at any time. Mix and match the multi EA 5100 accessory modules to suit your needs. The double furnace technology lets you achieve the best results for every sample matrix. Thanks to the easy-to-use tilting mechanism the analyzer can switch from vertical to horizontal combustion in few minutes. The multi EA 5100 is equipped with a safety system that guarantees maximum operational safety and economic life of crucial system components. Relevant system parameters are automatically monitored and optimized, guaranteeing a trouble-free and safe operation. The auto-protection system protects the analyzer from damage caused by particles, aerosols, and liquids. Optimal combustion for accurate measurements, the flame sensor guarantees matrix-optimized, quantitative combustion and prevents soot formation. Samples can be analyzed quickly and reliably.
Fast, Versatile, Sensitive
The multi EA 5100 guarantees competitive advantage of your lab in terms of cost-effectiveness and analysis quality. Fast analysis is possible in three minutes for liquids and six minutes for solids. With a high sample throughput up to 160 liquid samples and up to 90 solid samples per day, costs are kept very low. Reduced consumption of consumables and less time spent on maintenance, minimize costs even further. C/N/S/X testing is carried out in one analysis cycle, the change between C/N/S and X determination is fully automatic, with no conversion of the instrument required. The unmatched detector diversity of sulfur, nitrogen, carbon, and chlorine opens up a wide range of applications and offers the perfect solution for every elemental analysis task. The modular principle allows for the system to be designed individually – an extension is possible at any time should your requirements change. The HiPerSens detection provides for a broad linear measuring range and lowest limits of detection.
Flexible automation possibilities for a high sample throughput reduce the costs per analysis considerably. A wide range of accessories is offered to boost analysis throughput. Available accessories include an automatic boat drive (ABD) with cooled sample port for the automatic introduction of liquid and solid samples. It´s integrated flame sensor guarantees matrix-optimized, quantitative combustion and prevents soot formation, thereby solving a problem common to other conventional instruments. With this technology, samples can be analyzed quickly and reliably, even if their characteristics are unknown. A multi matrix sampler (MMS) is available for automatic introduction of up to 112 liquids or 35 solids, an autoinjector for safe semi-automated injection of liquids up to 100 μl, ideal for small sample series. For LPG and gas analysis, three different matrix-optimized modules are available. You can choose between the GSS module, a gas sampling system for introduction of unpressurized or pressurized gas samples, the LPG 2.0 module for direct dosing of pressurized liquefied gases, and the GSS/LPG combi module for dosing of liquefied and pressurized gases with separate sample branches to prevent cross-contamination. With its broad application spectrum and smart features, the multi EA 5100 is ideal for industrial control labs, contract labs and state authorities in the oil and gas, petrochemical and chemical industries. Applications include process control, material testing, and waste management. Features such as flame sensor technology for matrix-optimized sample digestion – including most difficult matrices such as oils, VGO, polymers and liquefied gases – and the integrated method library are indispensable for easy routine analysis.
Fast, Versatile, Sensitive
The multi EA 5100 guarantees competitive advantage of your lab in terms of cost-effectiveness and analysis quality. Fast analysis is possible in three minutes for liquids and six minutes for solids. With a high sample throughput up to 160 liquid samples and up to 90 solid samples per day, costs are kept very low. Reduced consumption of consumables and less time spent on maintenance, minimize costs even further. C/N/S/X testing is carried out in one analysis cycle, the change between C/N/S and X determination is fully automatic, with no conversion of the instrument required. The unmatched detector diversity of sulfur, nitrogen, carbon, and chlorine opens up a wide range of applications and offers the perfect solution for every elemental analysis task. The modular principle allows for the system to be designed individually – an extension is possible at any time should your requirements change. The HiPerSens detection provides for a broad linear measuring range and lowest limits of detection.
Flexible automation possibilities for a high sample throughput reduce the costs per analysis considerably. A wide range of accessories is offered to boost analysis throughput. Available accessories include an automatic boat drive (ABD) with cooled sample port for the automatic introduction of liquid and solid samples. It´s integrated flame sensor guarantees matrix-optimized, quantitative combustion and prevents soot formation, thereby solving a problem common to other conventional instruments. With this technology, samples can be analyzed quickly and reliably, even if their characteristics are unknown. A multi matrix sampler (MMS) is available for automatic introduction of up to 112 liquids or 35 solids, an autoinjector for safe semi-automated injection of liquids up to 100 μl, ideal for small sample series. For LPG and gas analysis, three different matrix-optimized modules are available. You can choose between the GSS module, a gas sampling system for introduction of unpressurized or pressurized gas samples, the LPG 2.0 module for direct dosing of pressurized liquefied gases, and the GSS/LPG combi module for dosing of liquefied and pressurized gases with separate sample branches to prevent cross-contamination. With its broad application spectrum and smart features, the multi EA 5100 is ideal for industrial control labs, contract labs and state authorities in the oil and gas, petrochemical and chemical industries. Applications include process control, material testing, and waste management. Features such as flame sensor technology for matrix-optimized sample digestion – including most difficult matrices such as oils, VGO, polymers and liquefied gases – and the integrated method library are indispensable for easy routine analysis.
Fast, Versatile, Sensitive
The multi EA 5100 guarantees competitive advantage of your lab in terms of cost-effectiveness and analysis quality. Fast analysis is possible in three minutes for liquids and six minutes for solids. With a high sample throughput up to 160 liquid samples and up to 90 solid samples per day, costs are kept very low. Reduced consumption of consumables and less time spent on maintenance, minimize costs even further. C/N/S/X testing is carried out in one analysis cycle, the change between C/N/S and X determination is fully automatic, with no conversion of the instrument required. The unmatched detector diversity of sulfur, nitrogen, carbon, and chlorine opens up a wide range of applications and offers the perfect solution for every elemental analysis task. The modular principle allows for the system to be designed individually – an extension is possible at any time should your requirements change. The HiPerSens detection provides for a broad linear measuring range and lowest limits of detection.
Flexible automation possibilities for a high sample throughput reduce the costs per analysis considerably. A wide range of accessories is offered to boost analysis throughput. Available accessories include an automatic boat drive (ABD) with cooled sample port for the automatic introduction of liquid and solid samples. It´s integrated flame sensor guarantees matrix-optimized, quantitative combustion and prevents soot formation, thereby solving a problem common to other conventional instruments. With this technology, samples can be analyzed quickly and reliably, even if their characteristics are unknown. A multi matrix sampler (MMS) is available for automatic introduction of up to 112 liquids or 35 solids, an autoinjector for safe semi-automated injection of liquids up to 100 μl, ideal for small sample series. For LPG and gas analysis, three different matrix-optimized modules are available. You can choose between the GSS module, a gas sampling system for introduction of unpressurized or pressurized gas samples, the LPG 2.0 module for direct dosing of pressurized liquefied gases, and the GSS/LPG combi module for dosing of liquefied and pressurized gases with separate sample branches to prevent cross-contamination. With its broad application spectrum and smart features, the multi EA 5100 is ideal for industrial control labs, contract labs and state authorities in the oil and gas, petrochemical and chemical industries. Applications include process control, material testing, and waste management. Features such as flame sensor technology for matrix-optimized sample digestion – including most difficult matrices such as oils, VGO, polymers and liquefied gases – and the integrated method library are indispensable for easy routine analysis.
Fast, Versatile, Sensitive
The multi EA 5100 guarantees competitive advantage of your lab in terms of cost-effectiveness and analysis quality. Fast analysis is possible in three minutes for liquids and six minutes for solids. With a high sample throughput up to 160 liquid samples and up to 90 solid samples per day, costs are kept very low. Reduced consumption of consumables and less time spent on maintenance, minimize costs even further. C/N/S/X testing is carried out in one analysis cycle, the change between C/N/S and X determination is fully automatic, with no conversion of the instrument required. The unmatched detector diversity of sulfur, nitrogen, carbon, and chlorine opens up a wide range of applications and offers the perfect solution for every elemental analysis task. The modular principle allows for the system to be designed individually – an extension is possible at any time should your requirements change. The HiPerSens detection provides for a broad linear measuring range and lowest limits of detection.
Flexible automation possibilities for a high sample throughput reduce the costs per analysis considerably. A wide range of accessories is offered to boost analysis throughput. Available accessories include an automatic boat drive (ABD) with cooled sample port for the automatic introduction of liquid and solid samples. It´s integrated flame sensor guarantees matrix-optimized, quantitative combustion and prevents soot formation, thereby solving a problem common to other conventional instruments. With this technology, samples can be analyzed quickly and reliably, even if their characteristics are unknown. A multi matrix sampler (MMS) is available for automatic introduction of up to 112 liquids or 35 solids, an autoinjector for safe semi-automated injection of liquids up to 100 μl, ideal for small sample series. For LPG and gas analysis, three different matrix-optimized modules are available. You can choose between the GSS module, a gas sampling system for introduction of unpressurized or pressurized gas samples, the LPG 2.0 module for direct dosing of pressurized liquefied gases, and the GSS/LPG combi module for dosing of liquefied and pressurized gases with separate sample branches to prevent cross-contamination. With its broad application spectrum and smart features, the multi EA 5100 is ideal for industrial control labs, contract labs and state authorities in the oil and gas, petrochemical and chemical industries. Applications include process control, material testing, and waste management. Features such as flame sensor technology for matrix-optimized sample digestion – including most difficult matrices such as oils, VGO, polymers and liquefied gases – and the integrated method library are indispensable for easy routine analysis.
Applications
Applications
-
Determination of N/S/Cl Contents in Lactic Acid (EN)
-
Determination of Total Sulfur and Total Nitrogen in Synthetic Caoutchouc (EN)
-
Determination of Total Chlorine in Different Types of Hydraulic Fluids (EN)
-
Ultra-sensitive High-throughput TS Analysis in Light Hydrocarbons ASTM D5453 (EN)
-
Determination in Light Hydrocarbons and Engine Fuel ASTM D5453 (EN)
-
Trace Nitrogen Determination in Adipic Acid (EN)
-
AppNote_EA_0024_en
-
Safe and Fast Determination of N/S/Cl Contents in Lactic Acid (JP)
-
Determination of EOX in Waste and Soil Samples According to DIN 38414-17 and EPA 9023 (EN)
-
EOX-Bestimmung in Abfall- und Bodenproben nach DIN 38414-17 und EPA 9023 (DE)
-
Determination of Total Halogens in Used Oil (EN)
-
Analysis of Trace Nitrogen in Highly Volatile Liquid Hydrocarbons by Oxidative Combustion with Chemiluminescence Detection According to UOP 981. (EN)
-
Analysis of Low Trace Sulfur in Highly Volatile Liquid Hydrocarbons by Oxidative Combustion and UV Fluorescence According to UOP 987 Method A (EN)
-
Determination of Total Chlorine and Organically Bound Chlorine in Pulp, Paper and Secondary Pulp According to ISO 11480 with an AOX Analyzer (DE)
-
Determination of Total Chlorine and Organically Bound Chlorine in Pulp, Paper and Secondary Pulp According to ISO 11480 with an AOX Analyzer (EN)
-
Détermination des halogènes totaux dans les huiles usagées (FR)
-
Determination of Total Chloride in LPG and Gaseous Hydrocarbons by Microcoulometry in Accordance with UOP 910 (EN)
-
Bestimmung des Gesamtchlorgehalts in verschiedenen Speiseölen
-
Determinatin of Sulfur in Mustard Oil and Other Edible Oils (EN)
-
Applikationsschrift stickstoffhaltige Speiseöle (DE)
-
Application Note EA0036 Notrogen Edible Oils (EN)
-
Vollautomatische Bestimmung des Gesamtschwefelgehalts in verschiedenen Speiseölen mittels Elementaranalyse und
-
Fully Automated Determination of Total Sulfur in Different Edible Oils by means of Combustion Elemental Analysis and UV-Fluorescence Detection
-
Applikationsschrift Palmöl (DE)
-
Application Note Palm oil (EN)
-
Extended Quality Check for Soy Oil – Determination of Nonmetal Elements Nitrogen, Sulfur and Chlorine by Combustion Elemental Analysis
-
Erweiterte Qualitätskontrolle für Sojaöl – Bestimmung der nichtmetallischen Elemente Stickstoff, Schwefel und Chlor durch verbrennungsbasierte Elementaranalyse
-
Fully Automated Determination of Total Sulfur Contents of Methanol and Ethanol in Accordance with DIN EN 15486 and ASTM D5453 (EN)
-
Application Note Determination of Widely Varying Chlorine Contents in Glycerol and MCT Oil by Combustion Elemental Analysis with Coulometric Titration (EN)
-
Determination of Total Sulfur, Total Nitrogen, and Total Chlorine Contents in Used Cooking Oil (UCO) and Related Bio-borne Fats by Means of Combustion Elemental Analysis (EN)
-
Combined Determination of Organic Carbon, Sulfur, Nitrogen, and Chlorine Contaminations on Catalyst Surfaces by Combustion Elemental Analysis (EN)
-
Automatisierte Bestimmung des Schwefelgehalts von Methanol und Ethanol mittels Elementaranalyse und UV-Fluoreszenz-Detektion nach DIN EN 15486 und ASTM D5453 (DE)
-
Bestimmung von Chlorgehalten in Glycerin und MCT-Öl mittels verbrennungsbasierter Elementaranalyse und coulometrischer Titration (DE)
-
Fast and Reliable TS Determination in Liquefied Pressurized Gases (LPG) according to ASTM D6667, ASTM D7551, and DIN EN 17178 (EN)
Applications
-
Determination of N/S/Cl Contents in Lactic Acid (EN)
-
Measurement of Soot in Ambient Air Based on VDI 2465-2 (EN)
-
Determination of EOX in Waste and Soil Samples According to DIN 38414-17 and EPA 9023 (EN)
-
EOX-Bestimmung in Abfall- und Bodenproben nach DIN 38414-17 und EPA 9023 (DE)
-
Determination of Total Halogens in Used Oil (EN)
-
Chlorbestimmung in Altöl (DE)
-
Determination of Total Chlorine and Organically Bound Chlorine in Pulp, Paper and Secondary Pulp According to ISO 11480 with an AOX Analyzer (DE)
-
Determination of Total Chlorine and Organically Bound Chlorine in Pulp, Paper and Secondary Pulp According to ISO 11480 with an AOX Analyzer (EN)
-
Détermination des halogènes totaux dans les huiles usagées (FR)
-
Manufacturer







