What are you looking for?
The multi X 2500 is a multi-talent in sum parameter analysis to be applied in many areas, from AOX/TOX, EOX, and POX monitoring in wastewater, sludge, and soil, TOC – important for wastewater analysis, to the determination of TX/TOX contents in challenging organic matrices. Benefit from a simple operation, unique application flexibility, and a high degree of automation. This directly results in reliable results and maximum sample throughput at minimal effort.
Optimal Adjustment for Each Sample Matrix
The innovative double furnace technology with tilting furnace combines the advantages of both, the vertical and horizontal sample feed and combustion, in one analysis system. A design that sets standards.
- Easy handling
- Plug-and-start technology
- Significantly reduced maintenance work
- High sample throughput in the vertical and horizontal mode
- Double furnace − optimum adaptation to each sample matrix
- Cooled titration cell − patented wide-range coulometer for comfortable analysis and long-term stable performance
- Speed load − highly efficient sample preparation systems enabling 24/7 operation
- Flame sensor − matrix-optimized quantitative combustion even for unknown samples
Brochures
| Title | Language | Info |
|---|---|---|
| Brochure AOX TOX Analysator multi X 2500 (DE) | de | PDF, 469 KB |
| Brochure AOX TOX EOX analyzer multi X 2500 (EN) | en | PDF, 432 KB |
| Produktkatalog Chemische Analyse (DE) | de | PDF, 909 KB |
| Product Guide Chemical Analysis (EN) | en | PDF, 886 KB |
| Flyer APU sim (DE) | de | PDF, 299 KB |
| Flyer APU sim (EN) | en | PDF, 294 KB |
| Flyer Solid Waste Analysis – Halogen Determination in Waste and Recycling (EN) | en | PDF, 1 MB |
| Brochure AOX TOX Analysator multi X 2500 (DE) | de | PDF, 1,000 KB |
| Brochure AOX TOX EOX analyzer multi X 2500 (EN) | en | PDF, 1 MB |
| Brochure AOX TOX EOX analyzer multi X 2500 (EN) | en | PDF, 1 MB |
| Flyer AOX-Probenvorbereitung – APU-Serie (DE) | de | PDF, 400 KB |
| Flyer AOX Sample Preparation – APU Systems (EN) | en | PDF, 325 KB |
| Analyse des déchets solides – Détermination des halogènes (FR) | fr | PDF, 1 MB |
| Flyer Chemical Recycling of Plastics: Analytical Solutions for Crucial Quality Gates (EN) | en | PDF, 301 KB |
Optimal Adjustment for Each Sample Matrix
The innovative double furnace technology with tilting furnace combines the advantages of both, the vertical and horizontal sample feed and combustion, in one analysis system. A design that sets standards.
- Easy handling
- Plug-and-start technology
- Significantly reduced maintenance work
- High sample throughput in the vertical and horizontal mode
- Double furnace − optimum adaptation to each sample matrix
- Cooled titration cell − patented wide-range coulometer for comfortable analysis and long-term stable performance
- Speed load − highly efficient sample preparation systems enabling 24/7 operation
- Flame sensor − matrix-optimized quantitative combustion even for unknown samples
Brochures
| Title | Language | Info |
|---|---|---|
| Brochure AOX TOX Analysator multi X 2500 (DE) | de | PDF, 469 KB |
| Brochure AOX TOX EOX analyzer multi X 2500 (EN) | en | PDF, 432 KB |
| Produktkatalog Chemische Analyse (DE) | de | PDF, 909 KB |
| Product Guide Chemical Analysis (EN) | en | PDF, 886 KB |
| Flyer APU sim (DE) | de | PDF, 299 KB |
| Flyer APU sim (EN) | en | PDF, 294 KB |
| Flyer Solid Waste Analysis – Halogen Determination in Waste and Recycling (EN) | en | PDF, 1 MB |
| Brochure AOX TOX Analysator multi X 2500 (DE) | de | PDF, 1,000 KB |
| Brochure AOX TOX EOX analyzer multi X 2500 (EN) | en | PDF, 1 MB |
| Brochure AOX TOX EOX analyzer multi X 2500 (EN) | en | PDF, 1 MB |
| Flyer AOX-Probenvorbereitung – APU-Serie (DE) | de | PDF, 400 KB |
| Flyer AOX Sample Preparation – APU Systems (EN) | en | PDF, 325 KB |
| Analyse des déchets solides – Détermination des halogènes (FR) | fr | PDF, 1 MB |
| Flyer Chemical Recycling of Plastics: Analytical Solutions for Crucial Quality Gates (EN) | en | PDF, 301 KB |
Optimal Adjustment for Each Sample Matrix
The innovative double furnace technology with tilting furnace combines the advantages of both, the vertical and horizontal sample feed and combustion, in one analysis system. A design that sets standards.
- Easy handling
- Plug-and-start technology
- Significantly reduced maintenance work
- High sample throughput in the vertical and horizontal mode
- Double furnace − optimum adaptation to each sample matrix
- Cooled titration cell − patented wide-range coulometer for comfortable analysis and long-term stable performance
- Speed load − highly efficient sample preparation systems enabling 24/7 operation
- Flame sensor − matrix-optimized quantitative combustion even for unknown samples
Brochures
| Title | Language | Info |
|---|---|---|
| Brochure AOX TOX Analysator multi X 2500 (DE) | de | PDF, 469 KB |
| Brochure AOX TOX EOX analyzer multi X 2500 (EN) | en | PDF, 432 KB |
| Produktkatalog Chemische Analyse (DE) | de | PDF, 909 KB |
| Product Guide Chemical Analysis (EN) | en | PDF, 886 KB |
| Flyer APU sim (DE) | de | PDF, 299 KB |
| Flyer APU sim (EN) | en | PDF, 294 KB |
| Flyer Solid Waste Analysis – Halogen Determination in Waste and Recycling (EN) | en | PDF, 1 MB |
| Brochure AOX TOX Analysator multi X 2500 (DE) | de | PDF, 1,000 KB |
| Brochure AOX TOX EOX analyzer multi X 2500 (EN) | en | PDF, 1 MB |
| Brochure AOX TOX EOX analyzer multi X 2500 (EN) | en | PDF, 1 MB |
| Flyer AOX-Probenvorbereitung – APU-Serie (DE) | de | PDF, 400 KB |
| Flyer AOX Sample Preparation – APU Systems (EN) | en | PDF, 325 KB |
| Analyse des déchets solides – Détermination des halogènes (FR) | fr | PDF, 1 MB |
| Flyer Chemical Recycling of Plastics: Analytical Solutions for Crucial Quality Gates (EN) | en | PDF, 301 KB |
The innovative double furnace technology with tilting furnace combines the advantages of both, the vertical and horizontal sample feed and combustion, in one analysis system. A design that sets standards.
Environmental Analysis Made Easy
In environmental monitoring as well as in process and quality control, the determination of organically bound halogens which can be adsorbed on activated carbon is very important for the evaluation of water and wastewater quality. With the multi X 2500, Analytik Jena provides a flexible, future-oriented system for analysis of halogen sum parameters that meets the requirements of every laboratory. multi X 2500 is the answer to permanently increasing costs and a growing number of samples. Developed as a particularly efficient and low-maintenance AOX analyzer with extremely low operational costs, multi X 2500 provides you with reliability, true flexibility, precision, and unbelivable ease of use. Straightforward operation, rapid operational readiness, and a minimum maintenance effort are only a few of the many advantages the multi X 2500 has to offer. The intelligent multiWin software, the fast changeover between column and batch method, and the user-friendly design ensure outstanding ease of use and efficiency.
Sophisticated automatic sampling systems allow in combination with our versatile sample preparation systems of the APU and AFU series both, fully and partially automated AOX analysis. Perfectly harmonized concepts of sample preparation and analysis. Remain flexible and cost-effective with a system that greatly minimizes idle time and increases the throughput of AOX samples. The innovative double furnace technology with tilting furnace combines the advantages of vertical and horizontal combustion in one analysis system. A design that sets standards. Whether ultra-fast AOX routine analysis in the vertical operation mode or reliable determination of the smallest EOX trace in the horizontal operation mode, double furnace technology allows you to freely select the best combustion mode for your application.
Environmental Analysis Made Easy
In environmental monitoring as well as in process and quality control, the determination of organically bound halogens which can be adsorbed on activated carbon is very important for the evaluation of water and wastewater quality. With the multi X 2500, Analytik Jena provides a flexible, future-oriented system for analysis of halogen sum parameters that meets the requirements of every laboratory. multi X 2500 is the answer to permanently increasing costs and a growing number of samples. Developed as a particularly efficient and low-maintenance AOX analyzer with extremely low operational costs, multi X 2500 provides you with reliability, true flexibility, precision, and unbelivable ease of use. Straightforward operation, rapid operational readiness, and a minimum maintenance effort are only a few of the many advantages the multi X 2500 has to offer. The intelligent multiWin software, the fast changeover between column and batch method, and the user-friendly design ensure outstanding ease of use and efficiency.
Sophisticated automatic sampling systems allow in combination with our versatile sample preparation systems of the APU and AFU series both, fully and partially automated AOX analysis. Perfectly harmonized concepts of sample preparation and analysis. Remain flexible and cost-effective with a system that greatly minimizes idle time and increases the throughput of AOX samples. The innovative double furnace technology with tilting furnace combines the advantages of vertical and horizontal combustion in one analysis system. A design that sets standards. Whether ultra-fast AOX routine analysis in the vertical operation mode or reliable determination of the smallest EOX trace in the horizontal operation mode, double furnace technology allows you to freely select the best combustion mode for your application.
Environmental Analysis Made Easy
In environmental monitoring as well as in process and quality control, the determination of organically bound halogens which can be adsorbed on activated carbon is very important for the evaluation of water and wastewater quality. With the multi X 2500, Analytik Jena provides a flexible, future-oriented system for analysis of halogen sum parameters that meets the requirements of every laboratory. multi X 2500 is the answer to permanently increasing costs and a growing number of samples. Developed as a particularly efficient and low-maintenance AOX analyzer with extremely low operational costs, multi X 2500 provides you with reliability, true flexibility, precision, and unbelivable ease of use. Straightforward operation, rapid operational readiness, and a minimum maintenance effort are only a few of the many advantages the multi X 2500 has to offer. The intelligent multiWin software, the fast changeover between column and batch method, and the user-friendly design ensure outstanding ease of use and efficiency.
Sophisticated automatic sampling systems allow in combination with our versatile sample preparation systems of the APU and AFU series both, fully and partially automated AOX analysis. Perfectly harmonized concepts of sample preparation and analysis. Remain flexible and cost-effective with a system that greatly minimizes idle time and increases the throughput of AOX samples. The innovative double furnace technology with tilting furnace combines the advantages of vertical and horizontal combustion in one analysis system. A design that sets standards. Whether ultra-fast AOX routine analysis in the vertical operation mode or reliable determination of the smallest EOX trace in the horizontal operation mode, double furnace technology allows you to freely select the best combustion mode for your application.
Environmental Analysis Made Easy
In environmental monitoring as well as in process and quality control, the determination of organically bound halogens which can be adsorbed on activated carbon is very important for the evaluation of water and wastewater quality. With the multi X 2500, Analytik Jena provides a flexible, future-oriented system for analysis of halogen sum parameters that meets the requirements of every laboratory. multi X 2500 is the answer to permanently increasing costs and a growing number of samples. Developed as a particularly efficient and low-maintenance AOX analyzer with extremely low operational costs, multi X 2500 provides you with reliability, true flexibility, precision, and unbelivable ease of use. Straightforward operation, rapid operational readiness, and a minimum maintenance effort are only a few of the many advantages the multi X 2500 has to offer. The intelligent multiWin software, the fast changeover between column and batch method, and the user-friendly design ensure outstanding ease of use and efficiency.
Sophisticated automatic sampling systems allow in combination with our versatile sample preparation systems of the APU and AFU series both, fully and partially automated AOX analysis. Perfectly harmonized concepts of sample preparation and analysis. Remain flexible and cost-effective with a system that greatly minimizes idle time and increases the throughput of AOX samples. The innovative double furnace technology with tilting furnace combines the advantages of vertical and horizontal combustion in one analysis system. A design that sets standards. Whether ultra-fast AOX routine analysis in the vertical operation mode or reliable determination of the smallest EOX trace in the horizontal operation mode, double furnace technology allows you to freely select the best combustion mode for your application.
Applications
Applications
-
Linearitätstest für die AOX-Bestimmung nach DIN EN ISO 9562 (Säulenmethode) (DE)
-
Bestimmung von adsorbierbaren organisch gebundenen Halogenen in stark salzhaltigen Wasserproben nach Festphasenextraktion (DE)
-
Bestimmung des AOX in Abwasserproben mittels Säulenmethode gemäß DIN EN ISO 9562 (DE)
-
Determination of AOX in Wastewater Samples by Column Method According to DIN EN ISO 9562 (EN)
-
Bestimmung des Parameters AOX in Klärschlamm mittels Schüttelmethode gemäß EN 16166 (DE)
-
Determination of AOX in Sewage Sludge Samples by Batch Method According to EN 16166 (EN)
-
Probenvorbereitung für die Bestimmung des AOF in Wässern nach E DIN 38409-59 (DE)
-
Sample Preparation for the Determination of AOF in Water Samples According to E DIN 38409-59 (EN)
-
Determination of EOX in Waste and Soil Samples According to DIN 38414-17 and EPA 9023 (EN)
-
EOX-Bestimmung in Abfall- und Bodenproben nach DIN 38414-17 und EPA 9023 (DE)
-
Determination of Total Halogens in Used Oil (EN)
-
Determination of Total Chlorine and Organically Bound Chlorine in Pulp, Paper and Secondary Pulp According to ISO 11480 with an AOX Analyzer (DE)
-
Determination of Total Chlorine and Organically Bound Chlorine in Pulp, Paper and Secondary Pulp According to ISO 11480 with an AOX Analyzer (EN)
-
Détermination des halogènes totaux dans les huiles usagées (FR)
-
Bestimmung des AOX in Grund-, Roh- und Trinkwasser sowie in Oberflächengewässern gemäß DIN EN ISO 9562 (DE)
-
Determination of AOX in Raw, Drinking, and Groundwater, as well as in Surface Water in Accordance with ISO 9562 (EN)
-
Applikationschrift Bestimmung des AOX in Abwasserproben nach Schüttelmethode gemäß DIN EN ISO 9562 (DE)
-
Application Note Determination of AOX in Wastewater Samples by Batch Method in Accordance with EN ISO 9562 (EN)
Applications
-
Linearity Test According to DIN EN ISO 9562 (Column Method) (EN)
-
Determination of Adsorbable Organic Halogens in Highly Saline Water Samples after Solid Phase Extraction (EN)
-
Linearitätstest für die AOX-Bestimmung nach DIN EN ISO 9562 (Säulenmethode) (DE)
-
Bestimmung von adsorbierbaren organisch gebundenen Halogenen in stark salzhaltigen Wasserproben nach Festphasenextraktion (DE)
-
Bestimmung des AOX in Abwasserproben mittels Säulenmethode gemäß DIN EN ISO 9562 (DE)
-
Determination of AOX in Wastewater Samples by Column Method According to DIN EN ISO 9562 (EN)
-
Bestimmung des Parameters AOX in Klärschlamm mittels Schüttelmethode gemäß EN 16166 (DE)
-
Determination of AOX in Sewage Sludge Samples by Batch Method According to EN 16166 (EN)
-
Probenvorbereitung für die Bestimmung des AOF in Wässern nach E DIN 38409-59 (DE)
-
Sample Preparation for the Determination of AOF in Water Samples According to E DIN 38409-59 (EN)
-
Determination of EOX in Waste and Soil Samples According to DIN 38414-17 and EPA 9023 (EN)
-
EOX-Bestimmung in Abfall- und Bodenproben nach DIN 38414-17 und EPA 9023 (DE)
-
Determination of Total Halogens in Used Oil (EN)
-
Chlorbestimmung in Altöl (DE)
-
Determination of Total Chlorine and Organically Bound Chlorine in Pulp, Paper and Secondary Pulp According to ISO 11480 with an AOX Analyzer (DE)
-
Determination of Total Chlorine and Organically Bound Chlorine in Pulp, Paper and Secondary Pulp According to ISO 11480 with an AOX Analyzer (EN)
-
Détermination des halogènes totaux dans les huiles usagées (FR)
-
Bestimmung des AOX in Grund-, Roh- und Trinkwasser sowie in Oberflächengewässern gemäß DIN EN ISO 9562 (DE)
-
Determination of AOX in Raw, Drinking, and Groundwater, as well as in Surface Water in Accordance with ISO 9562 (EN)
-
Applikationschrift Bestimmung des AOX in Abwasserproben nach Schüttelmethode gemäß DIN EN ISO 9562 (DE)
-
Application Note Determination of AOX in Wastewater Samples by Batch Method in Accordance with EN ISO 9562 (EN)
Applications
-
Linearitätstest für die AOX-Bestimmung nach DIN EN ISO 9562 (Säulenmethode) (DE)
-
Bestimmung von adsorbierbaren organisch gebundenen Halogenen in stark salzhaltigen Wasserproben nach Festphasenextraktion (DE)
-
Bestimmung des AOX in Abwasserproben mittels Säulenmethode gemäß DIN EN ISO 9562 (DE)
-
Determination of AOX in Wastewater Samples by Column Method According to DIN EN ISO 9562 (EN)
-
Bestimmung des Parameters AOX in Klärschlamm mittels Schüttelmethode gemäß EN 16166 (DE)
-
Determination of AOX in Sewage Sludge Samples by Batch Method According to EN 16166 (EN)
-
Probenvorbereitung für die Bestimmung des AOF in Wässern nach E DIN 38409-59 (DE)
-
Sample Preparation for the Determination of AOF in Water Samples According to E DIN 38409-59 (EN)
-
Determination of EOX in Waste and Soil Samples According to DIN 38414-17 and EPA 9023 (EN)
-
EOX-Bestimmung in Abfall- und Bodenproben nach DIN 38414-17 und EPA 9023 (DE)
-
Bestimmung des AOX in Grund-, Roh- und Trinkwasser sowie in Oberflächengewässern gemäß DIN EN ISO 9562 (DE)
-
Determination of AOX in Raw, Drinking, and Groundwater, as well as in Surface Water in Accordance with ISO 9562 (EN)
Applications
-
Linearitätstest für die AOX-Bestimmung nach DIN EN ISO 9562 (Säulenmethode) (DE)
-
Bestimmung von adsorbierbaren organisch gebundenen Halogenen in stark salzhaltigen Wasserproben nach Festphasenextraktion (DE)
-
Bestimmung des AOX in Abwasserproben mittels Säulenmethode gemäß DIN EN ISO 9562 (DE)
-
Determination of AOX in Wastewater Samples by Column Method According to DIN EN ISO 9562 (EN)
-
Bestimmung des Parameters AOX in Klärschlamm mittels Schüttelmethode gemäß EN 16166 (DE)
-
Determination of AOX in Sewage Sludge Samples by Batch Method According to EN 16166 (EN)
-
Probenvorbereitung für die Bestimmung des AOF in Wässern nach E DIN 38409-59 (DE)
-
Sample Preparation for the Determination of AOF in Water Samples According to E DIN 38409-59 (EN)
-
Determination of EOX in Waste and Soil Samples According to DIN 38414-17 and EPA 9023 (EN)
-
EOX-Bestimmung in Abfall- und Bodenproben nach DIN 38414-17 und EPA 9023 (DE)
-
Determination of Total Halogens in Used Oil (EN)
Manufacturer